.jpg)
Automatic Voltage Controller (AVC)
📍Manufactured in Mumbai, Maharashtra, India
<p> </p> <h3><span style="color:#000000">AUTOMATIC VOLTAGE CONTROLLER (AVC)</span></h3> <p> </p> <div class="row" style="box-sizing: border-box; margin-left: -15px; margin-right: -15px; color: rgb(112, 112, 112); font-family: "Open Sans", sans-serif; font-size: 15px; padding-top: 15px;"> <div class="col-sm-9 col-lg-9 col-md-9" style="box-sizing: border-box; position: relative; min-height: 1px; padding-left: 15px; padding-right: 15px; float: left; width: 658.125px;"> <p><span style="color:#000000">We are pleased to introduce <strong>ARZOO ENERGY</strong> as a technology & service partner of <strong>MANGAL ENGINEERS AND CONSULTANTS</strong> which is the country’s leading manufacturer & exporter of industrial <strong>Automatic Voltage Controllers (AVCs)</strong> up to 5000 KVA, <strong>Silicon Power Rectifiers</strong> (0 – 500V, up to 20000 Amps), <strong>Distribution & Power Transformer</strong> up to 15 MVA with 11/22/33 KV Class, <strong>HT & Built in AVRs, Dry type & Isolation Transformers</strong> along with <strong>Special Purpose Transformers</strong>. We command a highly skilled & experienced workforce at our plant guided by a team of competent Engineers having more than 30 years experience in this line.<br /> <br /> We believe in Quality oriented Products and with State of the art technology. We have established a renowned name as <strong>ARZOO ENERGY</strong> that has made a major Break-through in the field of engineering and electricity saving. Our high quality product and efficient services to our valued customers have enabled us with ample success. We would like to inform you that we are one of the leading manufacturers of above mentioned products and assure you that we are in a position to supply the same with best quality and strong service after sale.<br /> <br /> We would like to inform you that in our AVC & Rectifiers, we use Rolling Contact type Regulators <strong>where carbon roller are rolling on both sides of the coil, resulting in lesser wear and tear of the system. Also the overall cross-section area of the copper used in these regulators is more, resulting in increase in overall duty cycle of the equipment.</strong> The economic life of our stabilizers is easily 15 - 20 years. So, you can plan stabilizers as per your running load, keeping in mind your future expansion plans.<br /> <br /> <strong>VOLTAGE VARIATION:</strong><br /> Voltage variation is a common phenomenon all over the country. Generally voltage is low during daytime and high during the night hours. Moreover on holidays, peak hours, rainy days and when the agricultural load is switched off, the voltage rises quite sharply - which is more dangerous.<br /> <br /> Electrical equipments are designed for 230 Volts (single phase) or 400 Volts (3-phase) and operate with optimum efficiency at its rated voltage. 90% of industrial load consists of motors. Electric Motors draw considerably high current at HIGH voltage and increase energy consumption, increase MDI and reduce power factor etc. These excessive power losses of motors generated at higher voltage results in their premature failure.<br /> <br /> Similar is the case with Bulbs and Tubes, when voltage increases above 230 Volts. For example, at 270 Volts, the power consumption of 60W-bulb increases almost 40% and the life of bulb reduce from normal 1000 Hours to mere 100 Hours only (as per analysis report of ISI mark bulb manufacturers).<br /> <br /> The industrial units having high failure rate of electrical equipments i.e. Electric Motors (particularly smaller rating motors up to 7.5 HP), Bulbs, Tubes, Chokes, Contactor coils etc., should verify that it may be due to Higher Voltage.<br /> <br /> We have supplied number of AVCs to different industries and our clients have confirmed the under noted advantages after installing our AVCs.<br /> <br /> 1) Up to 60% Reduction in Breakdown of Electrical Equipments<br /> 2) 5 - 10% Savings in Electricity Costs (up to 30% on lighting load)<br /> 3) Reduction in MDI by 10 - 15%<br /> 4) Attractive Pay-back period of 6 - 12 months<br /> 5) Improvement in Power Factor<br /> 6) Uniform quality of end product & Improved Productivity of the plant<br /> 7) Depreciation @ 80% from Indian Income Tax Act.<br /> <br /> <strong>PAY-BACK PERIOD:</strong> Owing to its high efficiency (~99.5% in avg. running conditions) and associated benefits, the payback period for ARZOO’S make AVC is typically between 6-12 months, depending upon the number of working hours and duration of high voltage.<br /> <br /> As required, we are pleased to submit our most competitive offer for Servo Stabilizer in linear regulator technology as hereunder:<br /> <br /> ‘ARZOO’S make Natural Oil Cooled Type Automatic Voltage Regulator, Copper Wound Suitable for indoor use at a max. amb. Temp. of 45°C, 3-Phase, with the following specs:<br /> <br /> <strong>The standard equipment will primarily consist of the following:</strong><br /> a) Linear type continuously variable voltage regulator<br /> b) Mode of operation<br /> a. Auto Mode (Controller module for sensing and controlling)<br /> b. Manual Mode<br /> i) With help of Raise/Lower buttons<br /> ii) With help of 'T' Handle, if motor fails<br /> c) Over Voltage and Under Voltage Protection Inbuilt<br /> d) Single Phase protection Inbuilt<br /> e) Ammeter with CTs and selector switch<br /> f) Voltmeter Selector Switch for I/P & O/P<br /> g) Voltage adjust button on controller in Auto mode<br /> h) Indications - Input On, Low, High, O/p Cut off<br /> i) MCBs for control circuit<br /> j) Lifting Lugs<br /> k) Drain Valve<br /> l) Oil Level Gauge<br /> m) Rating Plate<br /> n) Earthing Terminal<br /> o) Junction Box<br /> p) Thermometer Pocket<br /> q) Wheels for Uni - directional movement</span></p> <div class="table-responsive" style="box-sizing: border-box;"> <table class="table" style="background-color:transparent; border-collapse:collapse; border-spacing:0px; margin-bottom:20px; max-width:100%; width:628px"> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>PARAMETER</strong></span></td> <td style="vertical-align:top"><span style="color:#000000"><strong>SPECIFICATION</strong></span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>TYPE</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">BALANCE / UNBALANCED 3 Phase 4 Wire</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>CAPACITY</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">UPTO 5000 KVA</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>VOLTAGE REGULATOR TECHNOLOGY</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">On load Linear Stepless Rolling Contact mechanism Technology with Carbon Roller Assembly and linearly variable continuous voltage regulator.</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>INPUT VOLTAGE</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">360 - 450V<br /> 350 - 450V<br /> 340 - 460V<br /> 330 - 470V<br /> 320 - 480V<br /> 300 - 500V<br /> 280 - 460V<br /> 260 - 460V<br /> 250 - 460V<br /> (Ph-Ph)</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>OUTPUT VOLTAGE</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">380 / 400 / 415 V±1% (Ph – Ph)</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>OUT PUT VOLTAGE ADJUSTMENT</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">380-415 V in 3 phase</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Connection</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">Star</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Operating Frequency</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">47 – 53 HZ</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Waveform</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">No distortion</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Output regulation</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">1% maximum from No load to full load</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Motor Drive</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">Heavy Duty Synchronous Motor</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>COOLING</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">ONAN</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Operating temp</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">Normal 0-45 C</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Temp Rise</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">45 C above ambient</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>DUTY CYCLE</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">100% continuous</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>LOAD CYCLE</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">100 % Continuous</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>CORE USED</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">CRGO M4 Grade 0.27mm thickness</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>COPPER USED</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">99.9 % pure Electrolytic Grade</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Buck-Boost Transformer</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">Yes, Series Buck Boost Double Wound Transformer</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>TESTING</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">Routine tests - No load, Full load, Short Circuit, Heat run, capacity, Range</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>ELECTRONIC CONTROL CIRCUIT</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">IC – Based</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>RESPONSE TIME</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">10 milli seconds</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>CORRECTION TIME</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">8-10 Volts/sec</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>OVER LOAD CAPACITY</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">Our Linear Regulator type Automatic Voltage Stabilizer will be very much suitable to withstand 120% over load</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Efficiency</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">more than 98%</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Standard</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">As per IS 9815</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>TERMINATIONS</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">Separate Suitable Aluminum Bus Bars will be provided in the Termination Box.</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>EXPECTED WORKING LIFE</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">More than 25 Years.</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>MODE OF OPERATION</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">AUTO MODE<br /> MANUAL MODE<br /> (i) With raise / lower switch<br /> (ii) With “T” handle</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>Controls</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">Control will be provided in the same system on the front of the equipment</span></td> </tr> </tbody> <tbody> <tr> <td style="vertical-align:top"><span style="color:#000000"><strong>TRANSFORMER OIL</strong></span></td> <td style="vertical-align:top"><span style="color:#000000">AS PER IS: 335</span></td> </tr> </tbody> </table> <p> </p> <p> </p> <p> </p> </div> </div> </div>
