
Precise Temperature Measurement Camera
📍Manufactured in Noida, Uttar Pradesh, India
<p> </p> <h4>Feature :</h4> <ul> <li>Frequency 50Hz, Gigabit network: support temperature data transmitting realtime</li> <li>Auto focus, fast and precise temperature measuring</li> <li>Mechanism - Automatic Alarm based image capture, review and save capability</li> <li>Calibrate Alarm Thresholds - Automatic</li> <li>Spot/line/area/isotherm analysis tools, simpler and more flexible to retrieve temperature data</li> <li>Compact size: easily install in small space</li> <li>Support multi-protocols: TCP, UDP, ICMP, DHCP, RTSP</li> <li>Patented intelligent compensated temperature measurement algorithm: accuracy of ±0.3℃</li> <li>People Count & Image Data Storage feature - Via Software</li> </ul> <p> </p> <p>Product Specification:</p> <p> </p> <table class="table table-bordered" style="border-collapse:collapse; border:1px solid rgb(222, 226, 230); color:rgb(33, 37, 41); font-family:-apple-system,blinkmacsystemfont,segoe ui,roboto,helvetica neue,arial,noto sans,sans-serif,apple color emoji,segoe ui emoji,segoe ui symbol,noto color emoji; font-size:16px; margin-bottom:1rem; width:100%"> <tbody> <tr> <th style="vertical-align:top">Model No.</th> <th style="text-align:center !important; vertical-align:top">SY300</th> <th style="text-align:center !important; vertical-align:top">SY600</th> </tr> <tr> <td colspan="3" style="text-align:center !important; vertical-align:middle">Specification</td> </tr> <tr> <td style="vertical-align:middle">Detector</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">VOx uncooled thermal FPA</td> </tr> <tr> <td style="vertical-align:middle">Visual Camera Resolution</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">1 MP</td> </tr> <tr> <td style="vertical-align:middle">Adjust date & time</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Available</td> </tr> <tr> <td style="vertical-align:middle">Interface for image transfer</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Via Software</td> </tr> <tr> <td style="vertical-align:middle">Resolution</td> <td style="text-align:center !important; vertical-align:middle">640×512</td> <td style="text-align:center !important; vertical-align:middle">384×288</td> </tr> <tr> <td colspan="3" style="text-align:center !important; vertical-align:middle">Temperature Measurement</td> </tr> <tr> <td style="vertical-align:middle">Measurement range</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">0℃〜60℃</td> </tr> <tr> <td style="vertical-align:middle">Thermal sensitivity (NETD) @30°C</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">0.04°C</td> </tr> <tr> <td style="vertical-align:middle">Flux</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">>100 people/minute</td> </tr> <tr> <td style="vertical-align:middle">Measurement mode</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Intelligent human face tracking and measuring</td> </tr> <tr> <td style="vertical-align:middle">High temperature alarm</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Pop out window, audible alarm, capture alarm</td> </tr> <tr> <td style="vertical-align:middle">Emissivity setting</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Available</td> </tr> <tr> <td style="vertical-align:middle">Infrared spectral band (Min)</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">8 (micrometer)</td> </tr> <tr> <td style="vertical-align:middle">Infrared spectral band (Max)</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">14 (micrometer)</td> </tr> <tr> <td style="vertical-align:middle">Image Palettes</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Adjustable</td> </tr> <tr> <td colspan="3" style="text-align:center !important; vertical-align:middle">Connector</td> </tr> <tr> <td style="vertical-align:middle">Network Protocol</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">TCP, UDP, ICMP, IGMP, DHCP, RTSP</td> </tr> <tr> <td style="vertical-align:middle">Network connector</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">RJ45</td> </tr> <tr> <td colspan="3" style="text-align:center !important; vertical-align:middle">Lens</td> </tr> <tr> </tr> <tr> <td style="vertical-align:middle">Focal length</td> <td style="text-align:center !important; vertical-align:middle">15mm</td> <td style="text-align:center !important; vertical-align:middle">7.8mm</td> </tr> <tr> <td style="vertical-align:middle">Focus</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Auto focus</td> </tr> <tr> <td style="vertical-align:middle">Temperature stabilization system of camera</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Available</td> </tr> <tr> <td style="vertical-align:middle">Through-the-lens direct temperature measurement capability</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Available</td> </tr> <tr> <td style="vertical-align:middle">Horizontal Field of View of Standard lens</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">25-30 (degree)/td></td> </tr> <tr> <td style="vertical-align:middle">Vertical Field of View of Standard lens</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">20-25 (degree)</td> </tr> <tr> <td style="vertical-align:middle">IFOV of Standard lens</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">1.3 (mRad)</td> </tr> <tr> <td style="vertical-align:middle">Minimum Focus distance</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">1.5 meter</td> </tr> <tr> <td colspan="3" style="text-align:center !important; vertical-align:middle">Power supply(Network)</td> </tr> <tr> <td style="vertical-align:middle">Power voltage</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">10-36V DC</td> </tr> <tr> <td style="vertical-align:middle">@25℃ Typical consumption</td> <td style="text-align:center !important; vertical-align:middle">≤3.3W</td> <td style="text-align:center !important; vertical-align:middle">≤3W</td> </tr> <tr> <td style="vertical-align:middle">Power protection</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Support over-voltage, under-voltage, reverse connection protection</td> </tr> <tr> <td style="vertical-align:middle">PoE</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Supports</td> </tr> <tr> <td colspan="3" style="text-align:center !important; vertical-align:middle">Physical character</td> </tr> <tr> </tr> <tr> <td style="vertical-align:middle">Dimension</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">55×55×119(mm)(length×width×height)</td> </tr> <tr> <td colspan="3" style="text-align:center !important; vertical-align:middle">Environment Adaptation</td> </tr> <tr> <td style="vertical-align:middle">Working temperature</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">-10℃〜+60℃</td> </tr> <tr> <td style="vertical-align:middle">Storage temperature</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">-20℃〜+65℃</td> </tr> <tr> <td style="vertical-align:middle">Weight</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">1050 gm</td> </tr> <tr> <td style="vertical-align:middle">Vibration</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">4.3 grandom vibration, all axes</td> </tr> <tr> <td style="vertical-align:middle">Humidity</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">95%, non-condensing</td> </tr> <tr> <td style="vertical-align:middle">IP Protection</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">IP65</td> </tr> <tr> <td style="vertical-align:middle">Certification</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">CE, FCC</td> </tr> <tr> <td colspan="3" style="text-align:center !important; vertical-align:middle">Software Support</td> </tr> <tr> <td style="vertical-align:middle">SDK</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Support</td> </tr> <tr> <td style="vertical-align:middle">Professional analysis software</td> <td colspan="2" style="text-align:center !important; vertical-align:middle">Support</td> </tr> </tbody> </table> <p> </p> <p> </p> <p> </p>
