
Master HE
📍Manufactured in GURGAON, Haryana, India
<p> </p> <p><span style="font-family:ubuntulight">Power Range: </span><span style="font-family:ubuntubold">100 - 800 kVA</span></p> <p> </p> <p> </p> <h3> </h3> <p>99.4% EFFICIENCY</p> <p>kVA / kW</p> <div class="formatted-description" style="box-sizing: border-box; font-family: ubuntulight;"> <p><strong>HE - High Efficiency</strong><br /> Master HE series is available from 100 to 800 kVA. The UPS feature a new on-line double-conversion technology utilising IGBT and DSP (Digital Signal Processor) control to provide maximum protection, power quality and green energy for any type of application including primary datacenters, disaster recover sites, telecoms rooms, industrial processes and security applications.<br /> High efficiency stands for higher active power available if compared with legacy UPS thanks to output unitary p.f. Nominal power is granted with no downgrading indipendently from operating temperature.</p> <p> </p> <p><strong>Zero impact source</strong><br /> Master HE has a zero impact on connected power sources - grid networks or generators:</p> <p><strong>≤ 3% input current distortion</strong><br /> Input power factor 0,99<br /> power walk-in function - to ensure a progressive rectifier start-up<br /> start-up delay function - to restart the rectifier when the mains power supply is restored.</p> <p><strong>Smart Grid Ready UPS</strong><br /> Master HE series UPS are ‘Smart Grid Ready’ and can be used within an energy storage solution, whilst simultaneously operating at the highest levels of efficiency and automatically selecting the most efficient operating mode based on the state of the lower grid network or generator supply. The UPS are designed to electronically interface with energy management systems within an ‘intelligent’ Smart Grid application.</p> <p><strong>Advanced supervision</strong><br /> Master HEP series UPS have a front panel graphic display providing UPS information, measurements, status updates and alarms in different languages, with wave form displays including voltage/current and provide a kWh reading that can be used to measure IT loads and calculate a datacenter PUE (power usage effectiveness) ratio.</p> <p><strong>Battery care system</strong><br /> Master HE series UPS include a range of features designed to prolong battery life and reduce their usage.</p> <p><strong>Output isolation transformer</strong></p> <ul> <li>Better load protection from DC/Battery problems</li> <li>The UPS can be supplied from two independent lines</li> <li>Fault on DC bus will not affect the by-pass availability</li> <li>High Short circuit current</li> <li>Higher immunity to harmonics or energy backfeed generated by the load.</li> </ul> <p> </p> <div class="search-intestation" style="box-sizing: border-box; font-family: ubuntulight;"> <div class="title" style="box-sizing: border-box; display: inline; margin-right: 5px; font-size: 14px; font-family: ubuntubold;">Technical specifications of the model</div> <select> <option value="319">MHE 100</option> <option value="320">MHE 120</option> <option value="321">MHE 160</option> <option value="322">MHE 200</option> <option value="323">MHE 250</option> <option value="324">MHE 300</option> <option value="325">MHE 400</option> <option value="326">MHE 500</option> <option value="327">MHE 600</option> <option value="328">MHE 800</option> </select></div> <div id="current-model" style="box-sizing: border-box; position: relative; clear: both; margin-bottom: 1em; font-family: ubuntulight;"> <div class="cnt" style="box-sizing: border-box;"> <div class="product_model resource" id="product_model_319" style="box-sizing: border-box; margin-bottom: 0.5em;"> <div class="exports pull-right" style="box-sizing: border-box; float: right;"> <div class="export pdf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/319-mhe-100.pdf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="PDF" src="https://www.riello-ups.in/assets/pdf-96df124c6a190ec941b3dbb7d3c7c6f5.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="PDF" /></a></div> <div class="export rtf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/319-mhe-100.rtf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="RTF" src="https://www.riello-ups.in/assets/rtf-65b862e3f32ce41d4d8f08bba05f22dc.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="RTF" /></a></div> </div> <table class="table table-striped technical-specifications" style="background-color:transparent; border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; margin-bottom:20px; max-width:100%; width:100%" summary="technical-specifications"> <thead> <tr> <th style="text-align:left; vertical-align:bottom">Models</th> <th style="text-align:left; vertical-align:bottom">MHE 100</th> </tr> </thead> <tbody> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">INPUT</td> </tr> <tr> <td style="vertical-align:top">Rated power</td> <td style="vertical-align:top">100000 VA</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">400 Vac three-phase</td> </tr> <tr> <td style="vertical-align:top">Voltage tolerance</td> <td style="vertical-align:top">+ 20% - 25%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">50/60 Hz with autorange</td> </tr> <tr> <td style="vertical-align:top">Frequency tolerance</td> <td style="vertical-align:top">45/65 Hz</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Power factor</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">0,99</td> </tr> <tr> <td style="vertical-align:top">Input current</td> <td style="vertical-align:top">141 A</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Current distorsion</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top"><3%</td> </tr> <tr> <td style="vertical-align:top">Soft start</td> <td style="vertical-align:top">0-100% in 10</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BY PASS</td> </tr> <tr> <td style="vertical-align:top">Rated voltage</td> <td style="vertical-align:top">400 Vac three-phase selectable 380 and 415</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">± 15% (selectable from ± 10% to ± 25% from front panel)</td> </tr> <tr> <td style="vertical-align:top">Rated frequency</td> <td style="vertical-align:top">50/60 Hz (autorange)</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">± 2% (selectable from ± 1% to ± 5% from front panel)</td> </tr> <tr> <td style="vertical-align:top">Rated current</td> <td style="vertical-align:top">141 A</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Number phases</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">3</td> </tr> <tr> <td style="vertical-align:top">Back-feed protection</td> <td style="vertical-align:top">yes</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Overload capacity Inx10ms</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">14</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OUTPUT and INVERTER OUTPUT</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Rated power</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">100000 VA</td> </tr> <tr> <td style="vertical-align:top">Active power</td> <td style="vertical-align:top">100000 W</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Number phases</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">3 + N</td> </tr> <tr> <td style="vertical-align:top">Crest factor (Ipeak/Irms)</td> <td style="vertical-align:top">3 : 1</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Waveform (Battery Mode)</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Sinewave</td> </tr> <tr> <td style="vertical-align:top">Dynamic stability</td> <td style="vertical-align:top">± 5% in 5 ms</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">same as the input (autorange)</td> </tr> <tr> <td style="vertical-align:top">Voltage distortion with distorcing load</td> <td style="vertical-align:top"><3%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage distortion with linear load</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top"><1%</td> </tr> <tr> <td style="vertical-align:top">Frequency stability</td> <td style="vertical-align:top">± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Overload</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">110% 125% 150% 200% of the rated current for 10' / 1' / 7</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">RECTIFIER OUTPUT</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Ripple</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top"><1%</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BATTERIES</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Type</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Maintenance-free sealed lead-acid</td> </tr> <tr> <td style="vertical-align:top">Maximum recharge current</td> <td style="vertical-align:top">0.2xC10</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">ENVIRONMENTAL</td> </tr> <tr> <td style="vertical-align:top">Altitude max</td> <td style="vertical-align:top">1000 m</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Color</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Dark grey RAL 7016</td> </tr> <tr> <td style="vertical-align:top">Remote controls</td> <td style="vertical-align:top">EPO and bypass</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Safety compliance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">EN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU</td> </tr> <tr> <td style="vertical-align:top">EMC conformance</td> <td style="vertical-align:top">EN 62040-2 and Directive 2014/30/EU</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Protection rating</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">IP20</td> </tr> <tr> <td style="vertical-align:top">Line-Interactive/Smart Active efficiency</td> <td style="vertical-align:top">up to 99,4%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Noise</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">63 dBA at 1 m</td> </tr> <tr> <td style="vertical-align:top">Remote signals</td> <td style="vertical-align:top">voltage free contacts (mains power failure, UPS on bypass, end of discharge pre-alarm, output 12Vdc 80mA)</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Operating temperature</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">0 ÷ 40 °C</td> </tr> <tr> <td style="vertical-align:top">Relative humidity</td> <td style="vertical-align:top">95% no condensing</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">DATA</td> </tr> <tr> <td style="vertical-align:top">Weight</td> <td style="vertical-align:top">730 kg</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Dimensions (h w d)</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">1900x800x850 mm</td> </tr> </tbody> </table> <p> </p> <p> </p> <p> </p> </div> </div> </div> </div>
