
SPH
📍Manufactured in GURGAON, Haryana, India
<p> </p> <div class="power_range" style="box-sizing: border-box; font-family: ubuntulight;">Power Range: <span style="font-family:ubuntubold">6 - 20 kVA</span></div> <div class="current_range" style="box-sizing: border-box; font-family: ubuntulight;"><span style="font-family:ubuntubold">Current Range</span>: <span style="font-family:ubuntubold">26 A</span></div> <div class="current_range" style="box-sizing: border-box; font-family: ubuntulight;"> </div> <div class="current_range" style="box-sizing: border-box; font-family: ubuntulight;"> <h3> </h3> <p>Absolute protection</p> <div class="formatted-description" style="box-sizing: border-box; font-family: ubuntulight;"> <p>SPH series is the ideal solution for protecting IT systems,</p> <p>Telecommunications equipment and mission critical systems such as safety devices, ensuring maximum power reliability.</p> <p>SPH Series is designed and built using state-of-the-art technology and Components to provide maximum protection to the powered loads with no impact on downstream systems and optimized energy savings.</p> <p> </p> <p>SPH series is the ideal solution for protecting IT systems,</p> <p>Telecommunications equipment and mission critical systems such as safety devices, ensuring maximum power reliability.</p> <p>SPH Series is designed and built using state-of-the-art technology and Components to provide maximum protection to the powered loads with no impact on downstream systems and optimized energy savings.</p> <p>The series includes 6 kVA single/single- phase and 10-20 kVA single/single-phase and three/single-phase models with on- line double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilized in terms of form and frequency.</p> <p>Input and output filters provide significant further immunity from mains disturbances and lightning strikes.</p> <p>In terms of technology and performance, SPH series is one of the best UPS available on the market today: selectable Eco Mode and Smart Active Mode functions; custom diagnostics LCD display, RS232 and USB interfaces with Power shield3 software, ESD input, interface slot with optional boards.</p> <h3><strong>High UPS reliability</strong></h3> <ul> <li>Total microprocessor control.</li> <li>Interruption-free static and manual bypass.</li> <li>Specifications guaranteed up to 40°C (the components are designed to work at high temperatures and thus are subject to less stress at normal temperatures).</li> </ul> <h3><strong>Parallelable</strong></h3> <p>Parallel configuration of 3 units for (2+1) redundant or power parallel system. The UPS continues to operate in parallel even if the connection cable is interrupted (Closed Loop).</p> <h3><strong>Operating mode selection</strong></h3> <p>The operating mode can be programmed via software or manually via the front display panel.</p> <ul> <li><strong>On line:</strong> double conversion Mode: for critical applications.</li> <li><strong>Eco Mode:</strong> to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply.</li> <li><strong>Smart Active:</strong> the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply.</li> <li><strong>Emergency:</strong> the UPS can be selected to function only when the mains power supply fails (emergency only mode).</li> <li><strong>Frequency converter</strong> operation (50 or 60 Hz).</li> </ul> <h3><strong>High quality output voltage</strong></h3> <ul> <li>Even with non-linear loads (IT loads with a crest factor of up to 3:1).</li> <li>High short circuit current on bypass.</li> <li>High overload capacity: 150% by inverter(even with mains failure).</li> <li>Filtered, stabilised and reliable voltage (double conversion on-line technology - VFI compliant with EN62040-3), with filters for the suppression of atmospheric disturbances.</li> <li>Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.</li> </ul> <h3><strong>Simplified installation</strong></h3> <ul> <li>UPS can be installed on a single-phase or three-phase distribution network.</li> <li>Output terminal board + 2 IEC sockets for powering local consumers (computers, modems, etc.).</li> <li>Simplified positioning (built-in castors).</li> </ul> <h3><strong>High battery reliability</strong></h3> <ul> <li>Automatic and manual battery test.</li> <li>Proper battery care is critical to ensuring correct UPS operation in emergency conditions. The Riello UPS battery care system consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life possible.</li> <li>Unlimited extendible runtime using matching Battery Boxes.</li> <li>The batteries do not cut in during mains failures of <40 ms (high hold up time) or when the input supply is between 84 V to 276 V.</li> <li> </li> </ul> <h3><strong>Low impact on the mains</strong></h3> <p>Sinusoidal uptake of input current on single- phase/single-phase series.</p> <h3><strong>Other features</strong></h3> <ul> <li>Advanced diagnostics: status, measurements and alarms available on custom LCD display.</li> <li>Low noise (<40 dBA): can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan (>20 kHz, value above audible range).</li> <li>Auto restart (automatic when mains supply is restored, programmable via software or display panel).</li> <li>Emergency function: the UPS can be selected to function only when the mains power supply fails (emergency lights).</li> <li>Back-feed protection standard: to prevent energy from being fed back to the network.</li> <li>UPS digital updating (flash upgradeable).</li> </ul> <h3><strong>Advanced communications</strong></h3> <ul> <li>Compatible with Riello UPS TeleNetGuard remote monitoring.</li> <li>Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows operating systems 10, 8, 7, Hyper-V, 2016, 2012, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems.</li> <li>RS232 serial and USB ports.</li> <li>Plug and play function.</li> <li>Slot for installation of communications boards.</li> </ul> <p> </p> <div class="search-intestation" style="box-sizing: border-box; font-family: ubuntulight;"> <div class="title" style="box-sizing: border-box; display: inline; margin-right: 5px; font-size: 14px; font-family: ubuntubold;">Technical specifications of the model</div> <select> <option value="477">SPM 6 ER</option> <option value="300">SPH 10 ER</option> <option value="299">SPH 20 ER</option> </select></div> <div id="current-model" style="box-sizing: border-box; position: relative; clear: both; margin-bottom: 1em; font-family: ubuntulight;"> <div class="cnt" style="box-sizing: border-box;"> <div class="product_model resource" id="product_model_477" style="box-sizing: border-box; margin-bottom: 0.5em;"> <div class="exports pull-right" style="box-sizing: border-box; float: right;"> <div class="export pdf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/477-spm-6-er.pdf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="PDF" src="https://www.riello-ups.in/assets/pdf-96df124c6a190ec941b3dbb7d3c7c6f5.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="PDF" /></a></div> <div class="export rtf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/477-spm-6-er.rtf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="RTF" src="https://www.riello-ups.in/assets/rtf-65b862e3f32ce41d4d8f08bba05f22dc.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="RTF" /></a></div> </div> <table class="table table-striped technical-specifications" style="background-color:transparent; border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; margin-bottom:20px; max-width:100%; width:100%" summary="technical-specifications"> <thead> <tr> <th style="text-align:left; vertical-align:bottom">Models</th> <th style="text-align:left; vertical-align:bottom">SPM 6 ER</th> </tr> </thead> <tbody> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OVERALL SPECIFICATION</td> </tr> <tr> <td style="vertical-align:top">Output power factor [pf]</td> <td style="vertical-align:top">0.9</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">INPUT</td> </tr> <tr> <td style="vertical-align:top">Voltage tolerance</td> <td style="vertical-align:top">220-230-240 Vac ± 20%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">±10 Hz</td> </tr> <tr> <td style="vertical-align:top">Input frequency</td> <td style="vertical-align:top">50/60 Hz</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BY PASS</td> </tr> <tr> <td style="vertical-align:top">Voltage tolerance</td> <td style="vertical-align:top">160 -276 Vac (Selectable in Eco Mode or Smart Active Mode)</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Selected frequency ±10%</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OUTPUT and INVERTER OUTPUT</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Number phases</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Single Phase</td> </tr> <tr> <td style="vertical-align:top">Crest factor (Ipeak/Irms)</td> <td style="vertical-align:top">3:1</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Waveform (Battery Mode)</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Sinusoidal</td> </tr> <tr> <td style="vertical-align:top">Frequency</td> <td style="vertical-align:top">50/60 Hz selectable or with automatic selection</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Load power factor</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">0.9</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BATTERIES</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Type</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">VRLA AGM maintenance-free lead based</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">ENVIRONMENTAL</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Color</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Dark grey RAL 7016</td> </tr> <tr> <td style="vertical-align:top">Communication</td> <td style="vertical-align:top">USB / R232 + slot for communication interface</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Safety compliance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">EN 62040-1</td> </tr> <tr> <td style="vertical-align:top">EMC conformance</td> <td style="vertical-align:top">EN 62040-2 Directives 2006/95/EC - 2004/108</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Marks</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">CE</td> </tr> <tr> <td style="vertical-align:top">Other compliances</td> <td style="vertical-align:top">BIS Registered</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Noise</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">< 40 dBA</td> </tr> <tr> <td style="vertical-align:top">Operating temperature</td> <td style="vertical-align:top">0 °C / +40 °C</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Relative humidity</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">< 95% non-condensing</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">DATA</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Weight</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">25.5 kg</td> </tr> <tr> <td style="vertical-align:top">Dimensions (h w d)</td> <td style="vertical-align:top">262X654X709 mm</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Input phases</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Single Phase</td> </tr> <tr> <td style="vertical-align:top">Output phases</td> <td style="vertical-align:top">Single Phase</td> </tr> </tbody> </table> <p> </p> <p> </p> <p> </p> </div> </div> </div> </div> </div>
