Loop PSC AND RCD Testers
📍Manufactured in Ahmedabad, Gujarat, India
<p> </p> <ul> <li style="text-align:left">Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above.</li> <li style="text-align:left">Dual Display allows simultaneous measurements like Loop & PFC/PSC.</li> <li style="text-align:left">Two wire connection for Loop L-L, L-N and PSC testing is possible.</li> <li style="text-align:left">Phase rotation, Voltage and Frequency measurements.</li> <li style="text-align:left">Lock-down test button for 'hands free' testing with auto-start operation.</li> <li style="text-align:left">Display and front panel keyboards with Backlight to be visible in dark places.</li> <li style="text-align:left">Water and Dust proof (IP54)</li> </ul> <p style="text-align:left"> </p> <div class="editor" style="box-sizing: border-box; margin: 0px; padding: 0px; border: 0px; font-variant-numeric: inherit; font-variant-east-asian: inherit; font-stretch: inherit; font-size: 17px; line-height: inherit; font-family: "Source Sans Pro", sans-serif; vertical-align: baseline; color: rgb(91, 91, 91);"> <h4>Loop Impedance</h4> <p> </p> <table style="border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; font-family:inherit; font-size:14px; font-stretch:inherit; font-style:inherit; font-variant:inherit; line-height:inherit; margin:0px 0px 1em; padding:0px; vertical-align:baseline; width:100%"> <tbody> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:165px">Function</th> <td style="vertical-align:baseline">L-PE ATT OFF</td> <td style="vertical-align:baseline">L-PE ATT ON</td> <td style="vertical-align:baseline">L-N / L-L</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Rated Voltage</th> <td colspan="2" style="vertical-align:baseline">230V (50/60Hz)</td> <td style="vertical-align:baseline">L-N: 230V (50/60Hz)<br /> L-L: 400V (50/60Hz)</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Operating Voltage</th> <td colspan="2" style="vertical-align:baseline">100 – 280V (45 – 65Hz)</td> <td style="vertical-align:baseline">100 – 500V (45 – 65Hz)</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Range (Auto-Ranging)</th> <td style="vertical-align:baseline">20/200/2000Ω</td> <td style="vertical-align:baseline">20/200/2000Ω<br /> (L-N<20Ω)</td> <td style="vertical-align:baseline">20Ω</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V</th> <td style="vertical-align:baseline">20Ω: 6A/40ms<br /> 200Ω: 2A/20ms<br /> 2000Ω: 15mA/500ms</td> <td style="vertical-align:baseline">L-N: 6A/60ms<br /> N-PE: 10mA/approx.5s</td> <td style="vertical-align:baseline">20Ω: 6A/20ms</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Accuracy</th> <td style="vertical-align:baseline">±3%rdg±4dgt (*1)</td> <td style="vertical-align:baseline">±3%rdg±6dgt (*1)</td> <td style="vertical-align:baseline">L-N: ±3%rdg±4dgt<br /> L-L: ±3%rdg±8dgt</td> </tr> </tbody> </table> <h4>PFC (L-PE) / PSC (L-N / L-L) (*2)</h4> <table style="border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; font-family:inherit; font-size:14px; font-stretch:inherit; font-style:inherit; font-variant:inherit; line-height:inherit; margin:0px 0px 1em; padding:0px; vertical-align:baseline; width:100%"> <tbody> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:165px">Function</th> <td style="vertical-align:baseline">PFC</td> <td style="vertical-align:baseline">PFC (ATT)</td> <td style="vertical-align:baseline">PSC</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Rated Voltage</th> <td colspan="2" style="vertical-align:baseline">230V (50/60Hz)</td> <td style="vertical-align:baseline">L-N: 230V (50/60Hz)<br /> L-L: 400V (50/60Hz)</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Operating Voltage</th> <td colspan="2" style="vertical-align:baseline">100 – 280V (45 – 65Hz)</td> <td style="vertical-align:baseline">100 – 500V (45 – 65Hz)</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Range (Auto-Ranging)</th> <td style="vertical-align:baseline">2000A/20kA</td> <td style="vertical-align:baseline">2000A/20kA (L-N<20Ω)</td> <td style="vertical-align:baseline">2000A/20kA</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V</th> <td style="vertical-align:baseline">20Ω: 6A/40ms<br /> 200Ω: 2A/20ms<br /> 2000Ω: 15mA/500ms</td> <td style="vertical-align:baseline">L-N: 6A/60ms<br /> N-PE: 10mA/approx.5s</td> <td style="vertical-align:baseline">20Ω: 6A/20ms</td> </tr> </tbody> </table> <h4>Phase Rotation</h4> <table style="border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; font-family:inherit; font-size:14px; font-stretch:inherit; font-style:inherit; font-variant:inherit; line-height:inherit; margin:0px 0px 1em; padding:0px; vertical-align:baseline; width:100%"> <tbody> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:165px">Operating Voltage</th> <td style="vertical-align:baseline">50 – 500V, 45 – 65Hz</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Remarks</th> <td style="vertical-align:baseline">Correct phase sequence: displayed “1.2.3” and <img src="https://www.kew-ltd.co.in/wp-content/uploads/2017/06/rcdlooppat_Testers/looppfcpsc_testers/kew_4140/recycle_right.gif" style="border:0px; box-sizing:border-box; font:inherit; height:auto; margin:0px; max-width:100%; padding:0px; vertical-align:baseline; width:20px" /> mark<br /> Reversed phase sequence: displayed “3.2.1” and <img src="https://www.kew-ltd.co.in/wp-content/uploads/2017/06/rcdlooppat_Testers/looppfcpsc_testers/kew_4140/recycle_right.gif" style="border:0px; box-sizing:border-box; font:inherit; height:auto; margin:0px; max-width:100%; padding:0px; vertical-align:baseline; width:20px" /> mark</td> </tr> </tbody> </table> <h4>Volts</h4> <table style="border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; font-family:inherit; font-size:14px; font-stretch:inherit; font-style:inherit; font-variant:inherit; line-height:inherit; margin:0px 0px 1em; padding:0px; vertical-align:baseline; width:100%"> <tbody> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:165px">Function</th> <td style="vertical-align:baseline">Volts</td> <td style="vertical-align:baseline">Frequency</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Measuring range</th> <td style="vertical-align:baseline">0 – 500V</td> <td style="vertical-align:baseline">45 – 65Hz</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Accuracy</th> <td style="vertical-align:baseline">±2%rdg±4dgt</td> <td style="vertical-align:baseline">±0.5%rdg±2dgt</td> </tr> </tbody> </table> <p style="text-align:justify"> </p> </div> <table class="mb0 specTable" style="border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; font-family:inherit; font-size:14px; font-stretch:inherit; font-style:inherit; font-variant:inherit; line-height:inherit; margin:0px; padding:0px; vertical-align:baseline; width:100%"> <tbody> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Applicable standards</th> <td style="vertical-align:baseline">IEC 61010-1 CAT III 300V (500V L to L),<br /> IEC 61010-031, IEC 61557-1, 3, 7, 10,<br /> IEC 60529 (IP54), IEC 61326 (EMC)</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Power source</th> <td style="vertical-align:baseline">1.5V AA batteries × 6 *Use of alkaline batteries (LR6) is recommended.</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Dimensions</th> <td style="vertical-align:baseline">84 (L) × 184 (W) × 133 (D) mm</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Weight</th> <td style="vertical-align:baseline">860g (including batteries)</td> </tr> <tr> <th style="background-color:rgb(224, 244, 253); text-align:left; vertical-align:baseline; width:154px">Included Accessories</th> <td style="vertical-align:baseline">Main cord (*3)<br /> Distribution board test lead (*4)<br /> 9155 (Shoulder strap)<br /> 9156 (Soft case)<br /> LR6 (Battery) × 6, Instruction manual</td> </tr> </tbody> </table> <p> </p> <p> </p> <p> </p>