
Multi Switch
📍Manufactured in GURGAON, Haryana, India
<p> </p> <p><span style="font-family:ubuntubold">Current Range</span><span style="font-family:ubuntulight">: </span><span style="font-family:ubuntubold">16 A</span></p> <p> </p> <p> </p> <h3> </h3> <p>16 A</p> <div class="formatted-description" style="box-sizing: border-box; font-family: ubuntulight;"> <p>Multi-Switch improves electrical supply continuity. The principle of operation guarantees a higher reliability level than that achieved using a single UPS (on-line with automatic bypass) or several UPS in parallel.</p> <p>PRINCIPLE OF OPERATION<br /> The Multi-Switch provides electrical distribution and remote management for up to eight network users, powered from either one or two direct mains supplies or UPS or a combination of both.<br /> Multi-Switch can connect each user (up to eight, each with a maximum power demand not greater than 3A), to either of the two power sources (A and B). Load demand is shown on the LCD. See “principle of operation” diagram.</p> <p>PROTECTION AGAINST POWER SUPPLY FAILURES<br /> If one of the two power sources fails or falls outside specification, Multi-Switch will transfer the connected loads to the second power source (switching is instantaneous even if the two sources are in phase).</p> <p>PROTECTION AGAINST FAULTS WITH THE LOAD<br /> If a fault occurs with one of the loads (for example due to a short-circuit or overload), Multi-Switch will disconnect the load to prevent disruption to the others.<br /> Multi-Switch protects sensitive installations from both power and hardware faults.</p> <p> </p> <p>• Full protection against mains failures and load faults<br /> • Flexible power sources: Multi-Switch can be powered from 2 different sources (2 mains supplies, 2 UPS or a combination of both. Note that the UPS can be of a different size)<br /> • Designed for installation in a 19" rack-mount cabinet<br /> • LCD to provide measurements/alarms/states information<br /> • Remote monitoring serial interface<br /> • No signal connection is required between Multi-Switch and the power sources or supplied<br /> hardware<br /> • Configuration software provided as standard.</p> <p>2-year warranty</p> <p> </p> <div class="search-intestation" style="box-sizing: border-box; font-family: ubuntulight;"> <div class="title" style="box-sizing: border-box; display: inline; margin-right: 5px; font-size: 14px; font-family: ubuntubold;">Technical specifications of the model</div> <select> <option value="341">MSW</option> </select></div> <div id="current-model" style="box-sizing: border-box; position: relative; clear: both; margin-bottom: 1em; font-family: ubuntulight;"> <div class="cnt" style="box-sizing: border-box;"> <div class="product_model resource" id="product_model_341" style="box-sizing: border-box; margin-bottom: 0.5em;"> <div class="exports pull-right" style="box-sizing: border-box; float: right;"> <div class="export pdf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/341-msw.pdf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="PDF" src="https://www.riello-ups.in/assets/pdf-96df124c6a190ec941b3dbb7d3c7c6f5.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="PDF" /></a></div> <div class="export rtf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/341-msw.rtf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="RTF" src="https://www.riello-ups.in/assets/rtf-65b862e3f32ce41d4d8f08bba05f22dc.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="RTF" /></a></div> </div> <table class="table table-striped technical-specifications" style="background-color:transparent; border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; margin-bottom:20px; max-width:100%; width:100%" summary="technical-specifications"> <thead> <tr> <th style="text-align:left; vertical-align:bottom">Models</th> <th style="text-align:left; vertical-align:bottom">MSW</th> </tr> </thead> <tbody> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">INPUT</td> </tr> <tr> <td style="vertical-align:top">Rated power</td> <td style="vertical-align:top">0000000 VA</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">180÷276 Vac, 50/60 Hz</td> </tr> <tr> <td style="vertical-align:top">Frequency</td> <td style="vertical-align:top">50/60 Hz</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OUTPUT and INVERTER OUTPUT</td> </tr> <tr> <td style="vertical-align:top">Active power</td> <td style="vertical-align:top">8 output sockets da 4A W</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Number phases</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">1</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">ENVIRONMENTAL</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Communication</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">DB9 with RS232 / Slot for communication interface</td> </tr> <tr> <td style="vertical-align:top">Protection rating</td> <td style="vertical-align:top">IP20</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Output sockets</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">8 IEC 320 (3A each)</td> </tr> </tbody> </table> <p> </p> <p> </p> <p> </p> </div> </div> </div> </div>
