
Master MPS
📍Manufactured in GURGAON, Haryana, India
<p> </p> <p><span style="font-family:ubuntulight">Power Range: </span><span style="font-family:ubuntubold">10 - 800 kVA</span></p> <p> </p> <h3> </h3> <p>Absolute protection</p> <div class="formatted-description" style="box-sizing: border-box; font-family: ubuntulight;"> <p>Master MPS (UPS system for CNC machines)series UPS devices ensure maximum protection and power quality for any type of load, especially for mission-critical applications, security systems and electro-medical equipment, industrial processes and telecommunications.</p> <p> </p> <p><strong>EASY SOURCE</strong><br /> <span style="font-family:ubuntulight">Master MPS makes powering UPS devices by power generators and MV/LV transformers easier and more efficient, reducing loss in systems and coils and correcting the power factor and eliminating harmonics by the loads powered by the UPS itself.</span><br /> <span style="font-family:ubuntulight">In addition to this, the progressive start-up of the rectifier and the possibility of reducing the recharge current of the batteries, allow for the containment of the input current absorbed and therefore do not overload the source, especially when the source is a generator.</span><br /> <br /> <strong>BATTERY CARE SYSTEM: MAXIMUM BATTERY CARE</strong><br /> <span style="font-family:ubuntulight">Normally the batteries are kept charged by the rectifier; when mains power fails, the UPS uses this energy source to power its utilities. Therefore, proper battery care is critical to ensuring correct UPS operation in emergency conditions.</span><br /> <span style="font-family:ubuntulight">Battery Care System consists of a series of features and capabilities that allow for battery management in order to obtain the best performance possible and extend their operating life.</span><br /> <br /> <span style="font-family:ubuntulight">• Dual level charging regime to optimize recharge currents and reduce charge times</span><br /> <span style="font-family:ubuntulight">• Temperature compensation and deep discharge protection to reduce overall battery ageing</span><br /> <span style="font-family:ubuntulight">• Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries</span><br /> <span style="font-family:ubuntulight">• Battery tests to diagnose, in advance, any reduction in performance or problems with the batteries.</span><br /> <br /> <span style="font-family:ubuntulight">Master MPS is also compatible with different battery technologies: vented open lead acid, VRLA AGM and NiCd.</span><br /> <br /> <strong>FLEXIBILITY</strong><br /> <span style="font-family:ubuntulight">Master MPS is suited to all types of applications, from computers to the most demanding industrial environments.</span><br /> <span style="font-family:ubuntulight">Thanks to the broad range of accessories and options, complex architectures and configurations can be created to ensure maximum power to critical loads:</span><br /> <span style="font-family:ubuntulight">expansions (in redundancy or power) may be made in already-operating parallel systems, even without having to switch off any UPS that are already operating and thus, maintaining power to utilities.</span><br /> <span style="font-family:ubuntulight">UGS and PSJ devices also ensure redundancy in the downstream distribution of the parallel system, creating a “selective” system that provides power to other connected utilities even when there are failures on one utility.</span><br /> <strong>MAXIMUM RELIABILITY AND AVAILABILITY</strong><br /> <span style="font-family:ubuntulight">Distributed or centralised parallel up to 8 units per redundant (N+1) or powerparallel. A parallel between models with different power levels is possible. Maximum levels of availability also in the event of an interruption to the parallel bus cable: the system is “FAULT TOLERANT”.</span><br /> <span style="font-family:ubuntulight">It is not affected by connection cable faults and continues powering the load without a continuity solution, signalling the anomaly with an alarm.</span><br /> <br /> <strong>OPTIONS</strong><br /> <span style="font-family:ubuntulight">• UGS - UPS Group Synchroniser Allows 2 or more non-parallel UPS devices to remain synchronised even during mains</span><br /> <span style="font-family:ubuntulight">power failure. The UGS also enables a Riello UPS to be synchronised with another power source that is independent and of a different power rating.</span><br /> <span style="font-family:ubuntulight">• PSJ - Parallel Systems Joiner Connects two UPS groups in parallel, hot (without output discontinuity) through a power</span><br /> <span style="font-family:ubuntulight">coupling switch. A UPS group (slave) is is permanently synchronised to the Master group both when the mains supply is present or not present (thanks to the UGS synchronising device) . If there is a failure on one of the UPS devices in parallel, it is cut-off. The PSJ will automatically connect the remaining UPS to the other group in parallel via an external bypass, in order to ensure the redundancy of the load.</span><br /> <br /> <strong>EASE OF INSTALLATION</strong><br /> <span style="font-family:ubuntulight">Master MPS requires only a very small space for installation (only 0.64 sqm for a 200KVA system); in addition, front access allows servicing of all major components from the front panel, making side access unnecessary. Given the upwards ventilation, Master Plus can be placed up against a wall, reducing the space to be left free, necessary in event the flow of hot air coming out the rear.</span><br /> <br /> <strong>SPECIFIC SOLUTIONS</strong><br /> <span style="font-family:ubuntulight">The UPS can be adapted to meet your requirements. Contact TEC to discuss the feasibility of specific solutions and options not listed in the catalogue.</span><br /> <br /> <strong>ADVANCED COMMUNICATION</strong><br /> <span style="font-family:ubuntulight">• Compatible with Teleguard for teleassistance.</span><br /> <span style="font-family:ubuntulight">• Advanced communication, multiplatform, for all operating systems and network environments: Supervision and</span><br /> <span style="font-family:ubuntulight">shutdown PowerShield3 software for Windows operating systems 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun</span><br /> <span style="font-family:ubuntulight">Solaris, Linux, Novell and other Unix operating systems.</span><br /> <span style="font-family:ubuntulight">• UPS is supplied with a cable for direct PC connection (Plug and PLay)</span><br /> <span style="font-family:ubuntulight">• RS232 double serial port</span><br /> <span style="font-family:ubuntulight">• Slot for network adapter installation; ESD contact (Emergency Switching Device) for switching off the UPS by</span><br /> <span style="font-family:ubuntulight">remote emergency button.</span><br /> <span style="font-family:ubuntulight">• Remote led mimic panel or graphic display.</span></p> <p> </p> <p> </p> <div class="search-intestation" style="box-sizing: border-box; font-family: ubuntulight;"> <div class="title" style="box-sizing: border-box; display: inline; margin-right: 5px; font-size: 14px; font-family: ubuntubold;">Technical specifications of the model</div> <select> <option value="157">MPM 10</option> <option value="158">MPM 15</option> <option value="159">MPM 20</option> <option value="160">MPM 30</option> <option value="161">MPM 40</option> <option value="162">MPM 60</option> <option value="163">MPM 80</option> <option value="164">MPM 100</option> <option value="457">MPM 120</option> <option value="165">MPT 10</option> <option value="166">MPT 15</option> <option value="167">MPT 20</option> <option value="168">MPT 30</option> <option value="169">MPT 40</option> <option value="170">MPT 60</option> <option value="171">MPT 80</option> <option value="172">MPT 100</option> <option value="173">MPT 120</option> <option value="174">MPT 160</option> <option value="175">MPT 200</option> <option value="458">MPT 250</option> <option value="459">MPT 300</option> <option value="460">MPT 400</option> <option value="461">MPT 500</option> <option value="462">MPT 600</option> <option value="463">MPT 800</option> </select></div> <div id="current-model" style="box-sizing: border-box; position: relative; clear: both; margin-bottom: 1em; font-family: ubuntulight;"> <div class="cnt" style="box-sizing: border-box;"> <div class="product_model resource" id="product_model_157" style="box-sizing: border-box; margin-bottom: 0.5em;"> <div class="exports pull-right" style="box-sizing: border-box; float: right;"> <div class="export pdf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/157-mpm-10.pdf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="PDF" src="https://www.riello-ups.in/assets/pdf-96df124c6a190ec941b3dbb7d3c7c6f5.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="PDF" /></a></div> <div class="export rtf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/157-mpm-10.rtf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="RTF" src="https://www.riello-ups.in/assets/rtf-65b862e3f32ce41d4d8f08bba05f22dc.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="RTF" /></a></div> </div> <table class="table table-striped technical-specifications" style="background-color:transparent; border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; margin-bottom:20px; max-width:100%; width:100%" summary="technical-specifications"> <thead> <tr> <th style="text-align:left; vertical-align:bottom">Models</th> <th style="text-align:left; vertical-align:bottom">MPM 10</th> </tr> </thead> <tbody> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">INPUT</td> </tr> <tr> <td style="vertical-align:top">Voltage</td> <td style="vertical-align:top">380 - 400 - 415 Vac three-phase</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">45 - 65 Hz</td> </tr> <tr> <td style="vertical-align:top">Frequency tolerance</td> <td style="vertical-align:top">± 2% (selectable from ± 1% to ± 5% from front panel)</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Soft start</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">0 - 100% in 120’’ (selectable)</td> </tr> <tr> <td style="vertical-align:top">Voltage Range</td> <td style="vertical-align:top">400 V + 20% /- 25%</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BY PASS</td> </tr> <tr> <td style="vertical-align:top">Rated voltage</td> <td style="vertical-align:top">360-400-420 Vac three-phase + N</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Rated frequency</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">50 or 60 Hz (selectable)</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OUTPUT and INVERTER OUTPUT</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Rated power</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">10000 VA</td> </tr> <tr> <td style="vertical-align:top">Active power</td> <td style="vertical-align:top">9000 W</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Output Voltage</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">220 - 230 - 240 Vac single-phase + N (selectable)</td> </tr> <tr> <td style="vertical-align:top">Crest factor (Ipeak/Irms)</td> <td style="vertical-align:top">3:1</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Static stability</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">± 1%</td> </tr> <tr> <td style="vertical-align:top">Dynamic stability</td> <td style="vertical-align:top">± 5% in 10 ms</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">50 or 60 Hz (selectable)</td> </tr> <tr> <td style="vertical-align:top">Voltage distortion with distorcing load</td> <td style="vertical-align:top">< 3% with non-linear load</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage distortion with linear load</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">< 1% with linear load</td> </tr> <tr> <td style="vertical-align:top">Frequency stability</td> <td style="vertical-align:top">0.05%</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OVERLOAD TIMES</td> </tr> <tr> <td style="vertical-align:top">100% < Load < 110%</td> <td style="vertical-align:top">60'</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">125% = Load < 150%</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">10'</td> </tr> <tr> <td style="vertical-align:top">Load = 150%</td> <td style="vertical-align:top">1'</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BATTERIES</td> </tr> <tr> <td style="vertical-align:top">Type</td> <td style="vertical-align:top">VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">ENVIRONMENTAL</td> </tr> <tr> <td style="vertical-align:top">Color</td> <td style="vertical-align:top">Dark grey RAL 7016</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Communication</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Double RS232 + dry contacts + 2 slots for communications interface</td> </tr> <tr> <td style="vertical-align:top">Safety compliance</td> <td style="vertical-align:top">EN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">EMC conformance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">EN 62040-2 and Directive 2014/30/EU</td> </tr> <tr> <td style="vertical-align:top">Protection rating</td> <td style="vertical-align:top">IP20</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Line-Interactive/Smart Active efficiency</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">up to 98%</td> </tr> <tr> <td style="vertical-align:top">Noise</td> <td style="vertical-align:top">60 dBA</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Operating temperature</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">0 °C/ +40 °C</td> </tr> <tr> <td style="vertical-align:top">Relative humidity</td> <td style="vertical-align:top"><95% non-condensing</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">DATA</td> </tr> <tr> <td style="vertical-align:top">Weight</td> <td style="vertical-align:top">200 kg</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Dimensions (h w d)</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">1400 x 555 x 740 mm</td> </tr> </tbody> </table> <p> </p> <p> </p> <p> </p> </div> </div> </div> </div>
