
Nature Switch GSM
📍Manufactured in Hyderabad, Moula-ali, India
<p> </p> <p><strong>Description</strong></p> <p>Internet enabled smart switching system offering real-time control and monitoring facility and multiple operation modes to suit your needs. Additional functionality of facilitating energy data, real-time alerts and interactive graphs and charts provide scope for data analysis and preventive maintenance steps.</p> <p><strong>Features</strong></p> <ul> <li>GSM/GPRS enabled communication technology</li> <li>Automatic ON/OFF via SMS/internet</li> <li>Multiple operation modes offering automatic switching based on:</li> <li>Natural light sensing</li> <li>Real time/astronomical clock</li> <li>Combination</li> <li>Automatic voltage based trip and reset</li> <li>Real-time alerts for field abnormalities</li> <li>Interactive data analysis</li> <li>Applicable to any kind of luminaries like LED, Solar lamps, HID, CFL, FTL, Induction etc.</li> <li>Easy integration without much re-wiring.</li> <li>Wide operating voltage range 150-300 VAC.</li> <li>Over Voltage sense, trip and auto reset.</li> <li>Low voltage sense, trip and auto reset.</li> <li>Immunity to dust, fog, cloud cover and moisture.</li> <li>Immunity to artificial light.</li> <li>Degree of protection conforms to IP65.</li> </ul> <p> </p> <p><strong>SPECIFICATION OF NATURE SWITCH-GSM FOR OUTDOOR LIGHTING</strong></p> <p><strong>APPLICATION:</strong> Nature Switch-GSM is offered for automation of electrical loads with remote management. It is applicable for any type of electrical load such as lighting, air conditioning, motors and other electrical appliances. The control unit is rated for IP65 which houses the SIM card. Once programmed it follows the switching cycle every day until changed.</p> <p>1) The switch must be suitable for direct installation in single-phase AC supply.<br /> 2) The operation voltage range must be 180 to 290VAC. It should be able to withstand a fault voltage of upto 440 VAC.<br /> <strong>3) OPTICAL SENSOR:</strong><br /> a) The sensor used should be reliable for calibration stability<br /> b) The sensing circuit should be sealed in a container meeting IP 65<br /> c) The sensor should be located behind a vertical wall to avoid accumulation of dust etc.</p> <p><strong>4) COMMUNICATION UNIT ( GSM MODULE):</strong><br /> Module – SIM 900<br /> Quad-Band 850/ 900/ 1800/ 1900 MHz<br /> Operation temperature: -30 °C to +80 °C<br /> <strong>5) OPERATIONAL SPECIFICATIONS:</strong><br /> Operating Voltage - 230VAC +10% 50 Hz<br /> Recommended Lighting Load - Up to 3000 watts<br /> Maximum Continuous Current - 16A<br /> Illuminance for Switching ON - < 60 lux for >30 seconds<br /> Illuminance for Switching OFF:<br /> a) In Field - >10 lux for >30 seconds<br /> b) In Lab - >60 lux for >30 seconds<br /> <strong>6) OPERATIONAL OPTIONS:</strong><br /> Manual ON/OFF<br /> Automatic Options<br /> · Sun based operation (On at Sunset, Off at Sunrise<br /> · Time based operation<br /> Single On/Off Cycle<br /> Double On/Off Cycle<br /> Triple On/Off Cycle</p> <p>· Combination of Sun and Time based operation<br /> On at Sunset-Off at Time<br /> On at Time-Off at Sunrise<br /> On at Sunset-Off at Time- On at Time off at Sunrise<br /> <strong>7) AUTO OVER/LOW VOLTAGE TRIP AND RESET:</strong><br /> Auto Over Voltage Trip - >280 VAC<br /> Auto Over Voltage Reset - < 265 VAC<br /> Auto Low Voltage Trip - < 150 VAC<br /> Auto Low Voltage Reset - >165 VAC<br /> <strong>8) TERMINAL CONSTRUCTION:</strong><br /> The terminals provision for connection to LIVE IN, NEUTRAL and LIVE OUT should be properly enclosed in such a way that no live part is open.<br /> 9) The switch must have an endurance of atleast 5,000 cycles at full rated load<br /> 10) The switch must perform in an ambient temperature range of –10 oC to +60oC<br /> 11) The switch must perform in open air with RH upto 95% at 25 oC<br /> 12) It must meet the drop and topple test from a height of 3 feet on any side at least for 5 Drops.<br /> 13) Product should conform to IP65.</p> <p> </p> <p> </p> <p> </p>
