
Multi Sentry
📍Manufactured in GURGAON, Haryana, India
<p> </p> <p><span style="font-family:ubuntulight">Power Range: </span><span style="font-family:ubuntubold">30 - 200 kVA</span></p> <p> </p> <p> </p> <h3> </h3> <p>10-200 kVA</p> <div class="formatted-description" style="box-sizing: border-box; font-family: ubuntulight;"> <p>MULTI SENTRY is a state-of-the-art uninterruptible power supply, achieving the highest possible level of on-line double-conversion performance (VFI-SS-111) as defined within IEC EN 62040-3.<br /> <br /> The UPS has been designed to protect critical information and telecommunications systems, networks, services and processes whose operation could be disrupted by poor power quality and/or breaks in their mains power supply.<br /> <br /> The sizes available include: 30-40-60-80-100-120-160-200 kVA all with a three-phase input and utput.<br /> The MULTI SENTRY UPS is one of the most efficient UPS available with a minimal impact on its environment and power sources.</p> <p> </p> <p><strong>ZERO IMPACT SOURCE</strong><br /> MULTI SENTRY UPS are easy to install, especially on sites where there is limited power capacity available, a standby generator and potentially harmonic compatibility issues:<br /> <br /> • low input current distortion - less than 3%<br /> • high input power factor 0.99<br /> • power walk-in function to achieve progressive rectifier start-up<br /> • delayed start-up on mains power supply return<br /> <br /> MULTI SENTRY also performs the role of a high specification filter, protecting its power supply sources (mains or generator) from any harmonics and reactive power generated by the loads it is powering.<br /> <br /> <strong>BATTERY CARE SYSTEM</strong><br /> The MULTI SENTRY Battery Care System optimises battery performance, to help extend their working life and ensure that the UPS can deliver its full-rated back-up time when called upon in an emergency.<br /> <br /> Battery recharge: MULTI SENTRY is designed to work with VRLA AGM and GEL lead-acid batteries including open-vented types, in addition to Ni-Cads. Specific management features include:<br /> <br /> • One-level recharge to meet the requirements of the most common VRLA AGM batteries<br /> • Two voltage level recharge meeting the IU characteristic<br /> • Restricted charging to reduce electrolyte consumption and extend the life of VRLA batteries<br /> <br /> Temperature compensation: to avoid excessive voltage being applied to the batteries in a high ambient<br /> <br /> Battery test: to detect performance degradation and predict battery failure.<br /> Deep discharge protection: to prevent the batteries being discharged below a level from which they cannot be recovered (especially when discharged over long periods with very low loads).<br /> Low AC ripple current: from a high-frequency battery charger, to ensure the batteries are not subjected to this damaging element commonly experienced with some other UPS and power supply designs.<br /> Wide input voltage range: from a rectifier that can work down to less than 40% of its nominal supply rating (at half load), removing the need to discharge the batteries.</p> <p><strong>FLEXIBILITY</strong><br /> MULTI SENTRY can be used for a wide range of applications, thanks to its configuration options, flexibility, accessories and performance levels:<br /> • suitable for powering capacitive loads, for example Blade servers - without any reduction in active power, from 0.9 leading to 0.9 lagging<br /> • modes of operation include: On-Line, Eco, Smart-Active and Stand-By/Off<br /> • frequency conversion mode<br /> • Power Share connections for priority-based load shedding when the mains power supply has failed<br /> • cold-start facility to switch the UPS on even without a mains power supply present<br /> • extensive back-up time options using battery extension cabinets<br /> • optional battery cabinet temperature sensor to assist the temperature compensating charger<br /> • optional battery chargers to optimize recharge times<br /> • optional dual input supplies<br /> • optional isolation transformers for Galvanic isolation and neutral connectivity<br /> <br /> <strong>ADVANCED COMMUNICATION</strong><br /> MULTI SENTRY has a large front panel graphic display providing information including: real-time measurements, operating status and alarms conditions - in eight different languages<br /> Advanced multiplatform communication, for all operating systems and network environments: PowerShield³ monitoring and shutdown software included with SNMP agent<br /> Compatible with TeleNetGuard for the remote assistance service<br /> RS232 or USB serial port<br /> Three communication slots for accessories including: network adapters and volt-free contacts<br /> REPO (Remote Emergency Power Off) to shut down the UPS remotely in an emergency<br /> Input for connection of an auxiliary contact for an external manual bypass<br /> Input for synchronisation with an external power source<br /> Graphic mimic panel display for remote connection.<br /> <br /> <strong>LOW MANAGEMENT COST</strong><br /> The MULTI SENTRY design provides exceptional performance and efficiency levels, within a very compact footprint and overall case design:<br /> • High efficiency up to 96% - saving up to 35% in dissipated energy in one year compared to a more traditional UPS (91%) resulting in a faster payback period of four years.<br /> • High output power factor which at 0,9pF (1pF for models 160-200 kVA) provides up to 15% ( 20% for models 160-200 kVA) more active power compared to a more traditionally sized UPS - providing greater system expansion margin for further load increases.</p> <p> </p> <div class="search-intestation" style="box-sizing: border-box; font-family: ubuntulight;"> <div class="title" style="box-sizing: border-box; display: inline; margin-right: 5px; font-size: 14px; font-family: ubuntubold;">Technical specifications of the model</div> <select> <option value="208">MST 30</option> <option value="209">MST 40</option> <option value="243">MST 60</option> <option value="244">MST 80</option> <option value="214">MST 100</option> <option value="338">MST 125</option> <option value="330">MST 160</option> <option value="331">MST 200</option> </select></div> <div id="current-model" style="box-sizing: border-box; position: relative; clear: both; margin-bottom: 1em; font-family: ubuntulight;"> <div class="cnt" style="box-sizing: border-box;"> <div class="product_model resource" id="product_model_208" style="box-sizing: border-box; margin-bottom: 0.5em;"> <div class="exports pull-right" style="box-sizing: border-box; float: right;"> <div class="export pdf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/208-mst-30.pdf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="PDF" src="https://www.riello-ups.in/assets/pdf-96df124c6a190ec941b3dbb7d3c7c6f5.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="PDF" /></a></div> <div class="export rtf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/208-mst-30.rtf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="RTF" src="https://www.riello-ups.in/assets/rtf-65b862e3f32ce41d4d8f08bba05f22dc.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="RTF" /></a></div> </div> <table class="table table-striped technical-specifications" style="background-color:transparent; border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; margin-bottom:20px; max-width:100%; width:100%" summary="technical-specifications"> <thead> <tr> <th style="text-align:left; vertical-align:bottom">Models</th> <th style="text-align:left; vertical-align:bottom">MST 30</th> </tr> </thead> <tbody> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">INPUT</td> </tr> <tr> <td style="vertical-align:top">Rated power</td> <td style="vertical-align:top">30000 VA</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">380/400/415 Vac three-phase + N</td> </tr> <tr> <td style="vertical-align:top">Voltage tolerance</td> <td style="vertical-align:top">± 20%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">40/72 Hz</td> </tr> <tr> <td style="vertical-align:top">Power factor</td> <td style="vertical-align:top">0.99</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BY PASS</td> </tr> <tr> <td style="vertical-align:top">Rated voltage</td> <td style="vertical-align:top">380/400/415 Vac three-phase + N</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">± 15% (selectable from ± 5% to ± 25%)</td> </tr> <tr> <td style="vertical-align:top">Rated frequency</td> <td style="vertical-align:top">50/60 Hz</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">± 5% (selectable from ± 0.25% to ± 10%)</td> </tr> <tr> <td style="vertical-align:top">Number phases</td> <td style="vertical-align:top">3 +N</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OUTPUT and INVERTER OUTPUT</td> </tr> <tr> <td style="vertical-align:top">Rated power</td> <td style="vertical-align:top">30000 VA</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Active power</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">27000 W</td> </tr> <tr> <td style="vertical-align:top">Output current</td> <td style="vertical-align:top">43 A</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Number phases</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">3 + N</td> </tr> <tr> <td style="vertical-align:top">Crest factor (Ipeak/Irms)</td> <td style="vertical-align:top">3 : 1</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Waveform (Battery Mode)</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Sinewave</td> </tr> <tr> <td style="vertical-align:top">Static stability</td> <td style="vertical-align:top">± 1%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Dynamic stability</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">± 3% in 10 ms</td> </tr> <tr> <td style="vertical-align:top">Frequency</td> <td style="vertical-align:top">50/60 Hz selectable</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage distortion with distorcing load</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">3%</td> </tr> <tr> <td style="vertical-align:top">Voltage distortion with linear load</td> <td style="vertical-align:top">1%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Overload</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">125% 150% 168% of the rated current for 10' / 1' / 5"</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BATTERIES</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Type</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Maintenance-free sealed lead acid</td> </tr> <tr> <td style="vertical-align:top">Recharge time</td> <td style="vertical-align:top">6 h</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">ENVIRONMENTAL</td> </tr> <tr> <td style="vertical-align:top">Color</td> <td style="vertical-align:top">Dark grey RAL 7016</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Remote controls</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">EPO and bypass</td> </tr> <tr> <td style="vertical-align:top">Communication</td> <td style="vertical-align:top">Double RS232/C , slot for SNMP adapter and slot for voltage free contacts.</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Safety compliance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">EN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU</td> </tr> <tr> <td style="vertical-align:top">EMC conformance</td> <td style="vertical-align:top">EN 62040-2 and Directive 2014/30/EU</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Protection rating</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">IP20</td> </tr> <tr> <td style="vertical-align:top">AC/AC efficiency</td> <td style="vertical-align:top">>94%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Line-Interactive/Smart Active efficiency</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">>98%</td> </tr> <tr> <td style="vertical-align:top">Noise</td> <td style="vertical-align:top"><40 dBA at 1 m - Smart Active Mode</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Remote signals</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">voltage free contacts</td> </tr> <tr> <td style="vertical-align:top">Operating temperature</td> <td style="vertical-align:top">0 ÷ 40 °C</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Relative humidity</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">95% no condensing</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">DATA</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Weight</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">335 kg</td> </tr> <tr> <td style="vertical-align:top">Dimensions (h w d)</td> <td style="vertical-align:top">1320x440x850 mm</td> </tr> </tbody> </table> <p> </p> <p> </p> <p> </p> </div> </div> </div> </div>
