Sentinel Dual SDU
📍Manufactured in GURGAON, Haryana, India
<p> </p> <p><span style="font-family:ubuntulight">Power Range: </span><span style="font-family:ubuntubold">4 - 10 kVA</span></p> <p> </p> <h3> </h3> <p><strong>HIGHLIGHTS</strong></p> <p>• Power factor 1 kW = kVA (from SDU 5000)<br /> • Parallelable up to 3 unit<br /> • Simplified installation<br /> • Operating mode selection<br /> • High quality output voltage<br /> • High battery reliability</p> <div class="formatted-description" style="box-sizing: border-box; font-family: ubuntulight;"> <p><strong>Sentinel Dual</strong> is the best solution for powering mission critical applications and electro-medical devices requiring maximum power reliability.<br /> Flexibility of installation and use (digital display, user-replaceable battery set), as well as the many communication options available, makes the <strong>Sentinel Dual</strong> suitable for many different applications from IT to security.<br /> <strong>Up to 3 Sentinel Duals can be operated in parallel</strong> in either capacity or N+1 redundant configuration offering increased reliability for critical system.<strong> The Sentinel Dual can be installed as Tower (floor standing) or Rack, ideal for network and server rack applications.</strong></p> <p>The <strong>Sentinel Dual range is available in 4 kVA 5-6-8-10 kVA/kW models with on-line double conversion technology (VFI)</strong>: the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilised in terms of voltage, form and frequency. In addition, the input and output filters significantly increase the load’s immunity to mains disturbances and lightning strikes.<br /> <strong>Technology and performance: selectable Economy Mode and Smart Active Mode functions.<br /> Diagnostics: Standard digital display, RS232 and USB interfaces with PowerShield3 software downloadable, communications slot for connectivity accessories</strong>.</p> <p> </p> <p><strong>Simplified installation</strong><br /> • <strong>Can be installed on the floor (tower version) or in rack mount cabinets (rack version)</strong>. The display panel can be rotated.<br /> • <strong>Low noise (<48 dBA)</strong>: can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan<br /> • <strong>External bypass option</strong> <strong>for maintenance </strong>with interruption-free switching <br /> • <strong>Operation guaranteed up to 40°C</strong> (the components are designed for high temperatures and are thus subject to less stress at normal temperatures)<br /> • <strong>Built-in IEC output sockets with thermal protection</strong>.</p> <p><strong>Operating mode selection</strong><br /> Functions can be programmed via software or manually via the front display panel.<br /> • <strong>On line: efficiency up to 95%</strong><br /> • <strong>Eco Mode</strong>: to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply<br /> • <strong>Smart Active</strong>: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply<br /> • <strong>Emergency</strong>: the UPS can be selected to function only when the mains power supply fails (emergency only mode).<br /> • <strong>Frequency converter operation</strong> (50 or 60 Hz).</p> <p><strong>High quality output voltage</strong><br /> • Even with non-linear loads (IT loads with a crest factor of up to 3:1)<br /> • High short circuit current on bypass<br /> • High overload capacity: 150% by inverter (even with mains failure)<br /> • Filtered, stabilised and reliable voltage (double conversion on-line technology (VFI compliant with EN62040-3), with filters for the suppression of atmospheric disturbances.<br /> • Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.</p> <p><strong>High battery reliability</strong><br /> • Automatic and manual battery test<br /> • Reduced ripple component (detrimental to the batteries) using a low ripple current discharge (LCRD) system<br /> • Batteries are user replaceable without switching off equipment and without interruption to the load (Hot Swap)<br /> • Unlimited extendible runtime using matching Battery Boxes<br /> • The batteries do not cut in during mains failures of <20 ms (high hold up time) or when the input supply is between 184 V to 276 V.</p> <p><strong>Emergency function</strong><br /> This configuration ensures the operation of those emergency systems that require continuous, reliable and long-lasting power supply in the event of a mains power failure, such as emergency lighting, fire detection/extinguishing systems and alarms. When the mains power supply fails, the inverter begins powering the loads with a progressive start-up (Soft Start) in order to prevent overload.</p> <p><strong>Battery optimisation</strong><br /> The wide input voltage range and a high hold-up time minimise battery usage and increase efficiency and battery life; for smaller power breaks, energy is drawn from a group of appropriately-sized capacitors.</p> <p><strong>EnergyShare</strong><br /> 10 A configurable IEC output sockets allow for runtime optimisation by programming the switching off of low priority loads on mains failure; alternatively, emergency loads that are normally not powered when mains is <br /> present can be activated.</p> <p><strong>Other features</strong><br /> • Selectable output voltage (220-230-240 V)<br /> • Dual input supplies configuration (SDU 10000 DI and SDU 10000 DI ER)<br /> • Auto-restart when mains power is restored (programmable via software)<br /> • Bypass on: when the machine is switched off, it automatically goes into bypass and battery charge mode<br /> • Minimum load switch-off<br /> • Low battery warning<br /> • Start-up delay<br /> • Total microprocessor and DSP control<br /> • Automatic bypass without interruption<br /> • Use of custom power modules<br /> • Status, measurements and alarms available on standard backlit display<br /> • UPS digital updating (flash upgradeable)<br /> • Output sockets protected with resettable thermal switch<br /> • Back-feed protection standard: to prevent energy from being fed back to the network<br /> • Manual switching to bypass.</p> <p><strong>Advanced communications</strong><br /> • Advanced multi-platform communications for all operating systems and network environments: PowerShield 3 monitoring and shutdown software for Windows operating systems 10, 8, 7, Hyper-V, 2019, 2016, 2012, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems<br /> • Plug and play function<br /> • USB port<br /> • RS232 serial port<br /> • Slot for installation of communications boards.</p> <p><strong>Unity Power Factor</strong><br /> • More power delivered<br /> • More real output power (W)</p> <p> </p> <div class="search-intestation" style="box-sizing: border-box; font-family: ubuntulight;"> <div class="title" style="box-sizing: border-box; display: inline; margin-right: 5px; font-size: 14px; font-family: ubuntubold;">Technical specifications of the model</div> <select> <option value="467">SDU 4000</option> <option value="401">SDU 5000</option> <option value="402">SDU 6000</option> <option value="403">SDU 6000 ER</option> <option value="453">SDU 8000</option> <option value="465">SDU 8000 TM</option> <option value="405">SDU 10000</option> <option value="406">SDU 10000 DI</option> <option value="407">SDU 10000 DI ER</option> <option value="466">SDU 10000 TM</option> </select></div> <div id="current-model" style="box-sizing: border-box; position: relative; clear: both; margin-bottom: 1em; font-family: ubuntulight;"> <div class="cnt" style="box-sizing: border-box;"> <div class="product_model resource" id="product_model_467" style="box-sizing: border-box; margin-bottom: 0.5em;"> <div class="exports pull-right" style="box-sizing: border-box; float: right;"> <div class="export pdf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/467-sdu-4000.pdf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="PDF" src="https://www.riello-ups.in/assets/pdf-96df124c6a190ec941b3dbb7d3c7c6f5.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="PDF" /></a></div> <div class="export rtf" style="box-sizing: border-box; display: inline;"><a href="https://www.riello-ups.in/product_models/467-sdu-4000.rtf" style="box-sizing: border-box; color: rgb(51, 51, 51); text-decoration-line: none; outline: none;" target="new"><img alt="RTF" src="https://www.riello-ups.in/assets/rtf-65b862e3f32ce41d4d8f08bba05f22dc.png" style="border-style:initial; border-width:0px; box-sizing:border-box; display:inline; height:auto; max-width:100%; vertical-align:middle" title="RTF" /></a></div> </div> <table class="table table-striped technical-specifications" style="background-color:transparent; border-collapse:collapse; border-spacing:0px; border:0px; box-sizing:border-box; margin-bottom:20px; max-width:100%; width:100%" summary="technical-specifications"> <thead> <tr> <th style="text-align:left; vertical-align:bottom">Models</th> <th style="text-align:left; vertical-align:bottom">SDU 4000</th> </tr> </thead> <tbody> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">INPUT</td> </tr> <tr> <td style="vertical-align:top">Dual Input</td> <td style="vertical-align:top">no</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Rated power</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">4000 VA</td> </tr> <tr> <td style="vertical-align:top">Voltage</td> <td style="vertical-align:top">220-230-240 Vac</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD</td> </tr> <tr> <td style="vertical-align:top">Frequency</td> <td style="vertical-align:top">50/60 Hz ± 5 Hz</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">50 Hz ± 20% / 60 Hz ± 20%</td> </tr> <tr> <td style="vertical-align:top">Power factor</td> <td style="vertical-align:top">>0.98</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Current distorsion</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">≤5%</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BY PASS</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage tolerance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)</td> </tr> <tr> <td style="vertical-align:top">Frequency tolerance</td> <td style="vertical-align:top">Selected frequency ± 5% (user configurable)</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Number phases</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">1</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OUTPUT and INVERTER OUTPUT</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Rated power</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">4000 VA</td> </tr> <tr> <td style="vertical-align:top">Active power</td> <td style="vertical-align:top">3600 W</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Crest factor (Ipeak/Irms)</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">3 : 1</td> </tr> <tr> <td style="vertical-align:top">Waveform (Battery Mode)</td> <td style="vertical-align:top">Sinewave</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Frequency</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">50/60 Hz selectable</td> </tr> <tr> <td style="vertical-align:top">Voltage distortion with distorcing load</td> <td style="vertical-align:top">≤ 3%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Voltage distortion with linear load</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">< 1%</td> </tr> <tr> <td style="vertical-align:top">Inverter efficiency at rated load</td> <td style="vertical-align:top">95% %</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OVERLOAD TIMES</td> </tr> <tr> <td style="vertical-align:top">100% < Load < 110%</td> <td style="vertical-align:top">1 minutes</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">110% < Load < 133%</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">activates the bypass after 1 min shut down after 1 hour</td> </tr> <tr> <td style="vertical-align:top">133% < Load < 150%</td> <td style="vertical-align:top">activates the bypass after 5 s shut down after 10 min</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">125% = Load < 150%</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">4 seconds</td> </tr> <tr> <td style="vertical-align:top">Load > 150%</td> <td style="vertical-align:top">0,5 second</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">BATTERIES</td> </tr> <tr> <td style="vertical-align:top">Type</td> <td style="vertical-align:top">VRLA AGM lead, maintenance-free</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Recharge time</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">4÷6 h</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">OPTIONS</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Parallel kit (to order with the UPS)</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Yes</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">ENVIRONMENTAL</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Altitude max</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">1000 m at nominal power (-1% power for every 100 m above 1000 m) 4000 m maximum</td> </tr> <tr> <td style="vertical-align:top">Color</td> <td style="vertical-align:top">Black RAL 9005</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Communication</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">USB / DB9 with RS232 and contacts / Slot for communication interface</td> </tr> <tr> <td style="vertical-align:top">Safety compliance</td> <td style="vertical-align:top">EN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">EMC conformance</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">EN 62040-2 and Directive 2014/30/EU</td> </tr> <tr> <td style="vertical-align:top">Accessories provided</td> <td style="vertical-align:top">USB cable; handles kit</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Protection rating</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">IP20</td> </tr> <tr> <td style="vertical-align:top">Surge capability</td> <td style="vertical-align:top">1 VDR x 300 Joules</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Marks</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">CE</td> </tr> <tr> <td style="vertical-align:top">Protections</td> <td style="vertical-align:top">Overload - short-circuit - overvoltage - undervoltage - temperature - low battery</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">AC/AC efficiency</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">95%</td> </tr> <tr> <td style="vertical-align:top">Line-Interactive/Smart Active efficiency</td> <td style="vertical-align:top">98%</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Noise</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top"><48 dBA</td> </tr> <tr> <td style="vertical-align:top">Operating temperature</td> <td style="vertical-align:top">0 ÷ 40 °C</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Relative humidity</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">5 - 95% no condensing</td> </tr> <tr> <td style="vertical-align:top">Output sockets</td> <td style="vertical-align:top">Terminal block + 2 IEC 320 C13 + 1 IEC 320 C19</td> </tr> <tr> <td colspan="2" style="background-color:rgb(171, 171, 171) !important; vertical-align:top">DATA</td> </tr> <tr> <td style="vertical-align:top">Weight</td> <td style="vertical-align:top">40 kg</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Dimensions (h w d)</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">448 x 131 x 640 / 3U x 19” x 640 mm</td> </tr> <tr> <td style="vertical-align:top">Input phases</td> <td style="vertical-align:top">1</td> </tr> <tr> <td style="background-color:rgb(249, 249, 249); vertical-align:top">Output phases</td> <td style="background-color:rgb(249, 249, 249); vertical-align:top">1</td> </tr> </tbody> </table> <p> </p> <p> </p> <p> </p> </div> </div> </div> </div>