IA AFA toxic fumes treatment plant was designed to neutralize fumes and organic substance retention. The tower is made entirely of PP, it’s base equipped with a washing liquid tank, suitably reinforced and fitted with necessary loading and unloading connections, overflow, visible level, recirculation pump support or connection.

 

The internal column is fitted with a 1 meter support grid equipped with moplen raschig rings, sprayed from above by a group of nozzles, sized in relation to pump flow rate and mounted on a PVC tube network. After passing through the rings in a opposite direction to wash water movement, gases are sprayed with water produced by the nozzle network and undergo further washing.

 

During the next step, gases pass through a droplet separator. It’s purpose is to retain water suspended particles, avoiding water escape from the tower. The tower casing is equipped with a porthole used for ring loading/unloading, nozzle maintenance and gas inlet and outlet. The re circulating pump is made from moplen. It’s vertical axis is housed in the tower’s lower part also used as a tank. The tank is designed to ensure recirculation of liquid inside the column. The pump is connected to the distribution network through a PVC pipe equipped with an adjustment valve.

 

The plant is CE-MARKED in compliance with Machinery Directive 2006/42/CE and Directives 2006/95/CE (low voltage) and 2004/108/CE 9 electromagnetic compatibility)

Specifications:

Model Diam. (mm.) Recycle Tank (lt.) Flow Pump lt/min Flow Fun (m3/h) TIME (sec.) Power (Kw) Meas. (cm.)
IA AFA 600/1 600 400 105 300 4,5 1,10 80 X 120 h 220